Back to Main Menue • SES-2000 compactSES-2000 lightSES-2000 standardSES-2000 mediumSES-2000 deepSES-2000 ROVSES-2000 Side ScanProcessing Software



System Variants: SES-2000 compact



SES-2000 compact Hardware

The system SES-2000 compact is based on the SES-96 product line, which is the first mobile parametric sediment echo sounder on the international market.
This system variant has a size of one half of a 19" device only. It is therefore very compact, light weight and usable even on the smallest vessel. Controlled via an USB interface with any external PC or Notebook running MS Windows it is a user friendly design too. It has not all features of the SES product line, but nevertheless it uses the same advanced technique of parametric acoustics and the user can benefit from all the known advantages, like small beam width, high resolution combined with deep penetration and accurate bathymetry measurements. The compact design without integrated industrial PC components results in a very affordable and reliable instrument for sub-bottom profiling applications.

The variant SES-2000 compact is designed for shallow water depth applications near the shore and inland waters down to 400 m.

Technical Parameters

Transducer:

nonlinear transmitter, linear receiver
beamwidth +/- 1,8° (0,22 x 0,22)m2

Transmitter: primary frequency:
secondary frequencies:
electrical power: 
source level:
100 kHz
5, 6, 8, 10, 12, 15 kHz
>12 kW
>236 dB/µPa re 1m
Pulse Width: 66 µSec ... 500 µSec

Pulse Repetition Rate:

up to 30/sec depending on range
Water Depth Range:

1 m ... 400 m
Operating Range:

5 m ... 200 m
Sound Velocity Range:

1400 m/s ... 1600 m/s
Penetration:

up to 50 m depending on sediments and frequency

Resolution:

sampling resolution: > 1 cm
multiple target resolution: > 5 cm
depending on frequency and operating range

Accuracy:


100 kHz : 0,02 m + 0,02 % of water depth
10 kHz : 0,04 m + 0,02 % of water depth

Trigger:


internal: depending on time control, output available
external: input available, TTL compatible

Receiver Channels:

1 channel primary frequency
1 channel secondary frequency

Gain Controls:

AGC or manual 0 ... 96 dB in 6 dB steps
Time Variable Gain
Digitization:

16 bit (real dynamic 14 bit)

Signal Processing: noise reduction: stacking rate up to 64
DSP to increase signal-to-noise ratio, resolution and
penetration,
online view of processed echo data,
replay of recorded data

Data Output: System control via USB 1.2 compatible interface with
external PC or Notebook and digital online storage of echo
envelope in chosen range, system parameters and navigation
to the Hard Disk of the Control PC running MS Windows
serial output for depth, time, position
online colour echo prints and thermal recorder prints

Data Input: serial input for navigation data (NMEA and ASCII compatible)
serial input for motion sensor for heave compensation

System Components: SES-2000 compact with integrated transmitter, receivers
and DSP´s: (0,35 x 0,30 x 0,40)m3 / weight 23 kg
transducer with 20 m cable (0,22 x 0,22 x 0,1 ) m3 /
25 kg weight (including cable)

Operating Conditions: 115-230 V AC +5%/-10%, 50 - 60 Hz,
power consumption < 800 W
operating temperature: 0°C ... 40 °C

Optional Features: module Side Scan with separate transducer



go to top