| Back to Main Menue SES-2000 compact SES-2000 light SES-2000 standard SES-2000 medium SES-2000 deep SES-2000 ROV SES-2000 Side Scan Processing Software | |
| System
Variants: SES-2000 compact |
SES-2000 compact Hardware |
|||
|
|
The system SES-2000 compact is based on the
SES-96 product line, which is the first mobile parametric sediment echo sounder on the international
market. |
| Technical
Parameters |
|||||
|
Transducer: |
nonlinear
transmitter, linear receiver beamwidth +/- 1,8° (0,22 x 0,22)m2 |
||||
| Transmitter: | primary
frequency: secondary frequencies: electrical power: source level: |
100 kHz 5, 6, 8, 10, 12, 15 kHz >12 kW >236 dB/µPa re 1m |
|||
| Pulse Width: | 66 µSec ...
500 µSec |
||||
| Pulse Repetition Rate: |
up to 30/sec depending on range | ||||
| Water Depth
Range: |
1 m ... 400 m | ||||
| Operating
Range: |
5 m ... 200 m | ||||
| Sound Velocity Range: |
1400 m/s ... 1600 m/s | ||||
| Penetration: |
up to 50 m depending on sediments and frequency |
||||
| Resolution: |
sampling resolution: > 1 cm multiple target resolution: > 5 cm depending on frequency and operating range |
||||
| Accuracy: |
100 kHz : 0,02 m + 0,02 % of water depth 10 kHz : 0,04 m + 0,02 % of water depth |
||||
| Trigger: |
internal: depending on time control, output available external: input available, TTL compatible |
||||
| Receiver Channels: |
1 channel primary frequency 1 channel secondary frequency |
||||
| Gain Controls: |
AGC or manual 0 ... 96 dB in 6 dB steps Time Variable Gain |
||||
| Digitization: |
16 bit (real dynamic 14 bit) |
||||
| Signal Processing: | noise reduction: stacking rate up to 64 DSP to increase signal-to-noise ratio, resolution and penetration, online view of processed echo data, replay of recorded data |
||||
| Data Output: | System control
via USB 1.2 compatible interface with external PC or Notebook and digital online storage of echo envelope in chosen range, system parameters and navigation to the Hard Disk of the Control PC running MS Windows serial output for depth, time, position online colour echo prints and thermal recorder prints |
||||
| Data Input: | serial input for navigation data (NMEA
and ASCII compatible) serial input for motion sensor for heave compensation |
||||
| System Components: | SES-2000
compact with integrated transmitter, receivers and DSP´s: (0,35 x 0,30 x 0,40)m3 / weight 23 kg transducer with 20 m cable (0,22 x 0,22 x 0,1 ) m3 / 25 kg weight (including cable) |
||||
| Operating Conditions: | 115-230 V AC +5%/-10%, 50 - 60 Hz, power consumption < 800 W operating temperature: 0°C ... 40 °C |
||||
| Optional Features: | module Side
Scan with separate transducer go to top |
||||