| Back to Main Menue SES-2000 compact SES-2000 light SES-2000 standard SES-2000 medium SES-2000 deep SES-2000 ROV SES-2000 Side Scan Processing Software | |
| System Variants:
SES-2000 deep |
SES-2000 deep Hardware |
|||
|
|
The system SES-2000 has all the advantages of the parametric acoustics, like the small beamwidth at low frequencies, deep penetrations with high resolutions of layers and objects and very accurate depth measurements with the high frequency. |
| Technical Parameters |
|||||
|
Transducer: |
nonlinear transmitter, linear receiver beamwidth +/- 1,5° (0,82 x 0,75)m2 |
||||
| Transmitter: | primary
frequency: secondary frequencies: electrical power: source level: electronical beam stabilization |
35 kHz 2, 3.5, 4, 5 kHz >80 kW >249 dB/µPa re 1m |
|||
| Pulse Width: | 200 µSec ...
3000 µSec chirp signals (2kHz to 5kHz) |
||||
| Pulse Repetition Rate: |
up to 30/sec depending on range | ||||
| Water Depth Range: |
5 m ... 6000 m | ||||
| Operating
Range: |
5 m ... 500 m | ||||
| Sound Velocity Range: |
1400 m/s ... 1600 m/s | ||||
| Penetration: |
up to 150 m depending on sediments and frequency |
||||
| Resolution: |
sampling resolution: > 1 cm multiple target resolution: > 15 cm depending on frequency and operating range |
||||
| Accuracy: |
35 kHz : 0,08 m +
0,04 % of water depth 4 kHz : 0,15 m + 0,04 % of water depth |
||||
| Trigger: |
internal: depending on time control, output available external: input available, TTL compatible |
||||
| Receiver Channels: |
1 channel primary frequency 1 channel secondary frequency |
||||
| Gain Controls: |
AGC or manual 0 ... 96 dB in 6 dB steps Time Variable Gain |
||||
| Digitization: |
16 bit (real dynamic 14 bit) |
||||
| Signal Processing: | noise reduction: stacking rate up to 64 DSP to increase signal-to-noise ratio, resolution and penetration, online view of processed echo data, replay of recorded data |
||||
| Data Output: | online storage of echo envelope in
chosen range, online storage of raw signal in chosen range, system parameters and navigation data on hard disk backup: USB 2.0 interface for HD, MO-Disk or others serial output for depth, time, position online colour echo prints and thermal recorder prints |
||||
| Data Input: | serial input for navigation data (NMEA compatible) serial input for motion sensor for heave compensation and roll/pitch compensation remote control via TCP/IP network |
||||
| System Components: | SES-2000 deep with integrated transmitter, receivers, DSP´s, 10,4" TFT panel and PC unit: (0,53 x 0,42 x 0,49)m3 / total weight 170kg (four electronic units) transducer (0,82 x 0,75 )m2 / weight 200kg (excluding cable) |
||||
| Operating Conditions: | 115-230 V AC +5%/-10%, 50 - 60 Hz, power consumption < 2500 W operating temperature: 0°C ... 40 °C |
||||
| Optional Features: |
water protected case in MIL standard go to top |
||||